Page 9
Downdraft Ventilators
REMOTE UP/DOWN CONTROL INSTALLATION
(OPTIONAL)
Installation
1. Using the template at right, lay out the 3-hole pattern on the
counter top. Mark the centers of the three holes to be drilled.
2. Carefully drill the three holes through the counter top. Be
careful not to damage or chip the counter top surface when
drilling the holes.
3. Remove the control from the plastic bag. Line the control up
with the three holes and position the control so it is parallel with
the front of the counter top.
4. Remove the two nylon thumbnuts from the plastic bag and
thread onto the two studs on the control from below the counter
top. Hand tighten only.
WARNING: To reduce the risk of burns or ignition
of clothing by reaching across burners, the re-
mote control must be mounted at least 4" away
from any cook top burner.
CUT OUT
ON DOTTED LINE
.250 DIA.
HOLES
.438
DIA.
HOLE
2.000
2.000
.750
.750
1.000
.625
.625
5. Remove cable from the plastic bag and plug into back of
control from below counter top. Route cable through cabinet
to lower right hand corner of downdraft. Plug other end of cable
into the downdraft unit as shown.
6. Stuff excess cable out of the way and secure the cable so it is
not damaged by items stored in the cabinet.
CABINET
FLOOR
LOWER
RIGHT SIDE
OF DOWNDRAFT
REMOTE
CABLE
When to use the Remote UP/DOWN Control
The Remote UP/DOWN Control should be used when your
cooktop has a burner that is within 4 inches of the UP/DOWN
Button on the downdraft chimney.
The Remote UP/DOWN Control
can be used for convenient UP/
DOWN operation of the downdraft chimney (even when a burner
is more than 4 inches from the UP/DOWN Button of the downdraft
chimney).
How to use the Remote UP/DOWN Control
Do not place the remote control where it will interfere with cooking,
where hot pans could be set, or where hot liquids could be spilled
on the control.
The Remote UP/DOWN Control disables the UP function of the
UP/DOWN Button on the downdraft chimney.
All Units